PRE-INSTALLATION OF REFRIGERATION

We undertake the pre-installation of refrigeration networks in newly constructed buildings for a better aesthetic result.

The installation of the networks is always done in consultation with the construction engineer and based on the capabilities of the air conditioning units to be installed.

During the installation of the piping, the following materials are used:

  • Copper pipes of refrigeration dimensions, suitable for air conditioning units.
  • Armaflex insulation, 9mm thick.
  • Cable 7*1.5, to meet the specifications of all machines.
  • Drainage pipe Ø16 or Ø18.
  • Spiral pipe Ø50 or Ø63 for floor piping & Ø20 for communication cable.
  • Anchoring in single or double brick or mortar, depending on the requirements of each project.
  • Pressing of the pipes for possible leak testing.